Description
FEW325
   - Bore Diameter                                                                          
050      DN 50 (2 in.)
   - Liner Material                                                                              
H        Hard rubber
   - Electrode Design                                                                        
1         Standard
   - Measuring Electrodes Material                                                 
S        Stainless steel 316
   - Grounding Accessories                                                             
4         2x Potential Equalizing Rings
(Stainless Steel)
   - Process Connection Type                                                       
A1       Flanges ANSI / ASME B16.5 / 16.47
series B Class 150
   - Process Connection Material                                                   
B        Carbon steel
   - Usage Certifications                                                                   
1         Standard (without PED)
   - Calibration Type                                                                         
A        Standard factory calibration
   - Temperature Range of Installation / Ambient                         1        
Standard design / -20 ... 60 °C (-4 ... 140 °F)
   Temperature Range
   - Name Plate                                                                                  
A        Adhesive label
   - Signal Cable Length and Type                                                 
2         10 m (approx. 30 ft) cable
   - Explosion Protection Certification                                             P        usFMc Div. 2
   - Protection Class Transmitter / Protection Class                     2        
IP 67 (NEMA 4X) / IP 68 (NEMA 6P), cable not fitted and 
   Sensor                                                                                                       not
potted, sensor is IP67 with PTFE liner
   - Cable Conduits                                                                           
B        NPT 1/2 in.
   - Power Supply                                                                              
3         100 ... 230 V AC, 60 Hz
   - Input and Output Signal Type                                                   
A        HART + 20 mA + Pulse + Contact
output
   - Configuration Type / Diagnostics Type                                    1        
Parameters set to factory defaults / Standard diagnostic 
                                                                                                                       functions
activated
   - Documentation Language                                                       
M5       English (standard)
   - Verification Type                                                                       
V3       VeriMaster
   - Potable Water and Food & Beverage Approvals                CWM     NSF material approval
   - Number of Testpoints                                                               
T3       3 Points