Description
FEW632.F2.A2.0080.A1.R2.B.1.S.0.E.76.Y.0.Y0.A-...CMA.CRA..CWC..K0.M5.....RCD.SC2.T1.TK1.TV3.V1
Complete with FET632
FEW632
- Explosion Protection Certification F2 cFMus Class 1 Div. 2 (Zone 2 / 21)
- Housing Type / Housing Material / Cable Glands A2 Remote / Aluminum / NPT 1/2 in.
- Meter Size 0080 DN 80 (3 in.)
- Process Connection Type A1 Flanges ASME CL 150 B16.5 up to DN 600, B16.47 serie B > DN 600
- Liner Material R2 Hard rubber
- Process Connection Material B Carbon steel
- Electrode Design 1 Standard
- Measuring Electrodes Material S Stainless steel 316Ti (1.4571)
- Grounding Electrode / Full Pipe Detection 0 No grounding electrode / No full pipe detection
- Grounding Accessories E Grounding Ring (2off), stainless steel, loose Item
- Protection Class Transmitter / Protection Class Sensor 76 Standard / IP 68 (630 series does not require a potting kit
- Power Supply Y Without
- Display 0 Without
- Outputs Y0 Without
- Design Level A Design Level A
- Calibration Certifications CMA ABB Standard
- Other Usage Certifications CRA Meter tube without PED certificate
- Potable Water and Food & Beverage Approvals CWC NSF61 (Product approval)
- Other Options K0 Without
- Documentation Language M5 English
- Calibration Type RCD 0,4 % Factory Calibration
- Signal Cable SC2 10 m (approx. 30 ft)
- Device Identification Plate T1 Stainless steel
- Temperature Range of Installation / Ambient Temp Range TK1 Standard design / -20 ... 60 °C (-4 ... 140 °F)
- Number of Testpoints TV3 3 Points
- Verification Capability V1 Enabled
Complete With
FET632 Electromagnetic Flowmeter, remote transmitter, for ProcessMaster FEW630 Sensor
- Explosion Protection Certification F2 cFMus Class 1 Div. 2 (Zone 2 / 21)
- Housing Type / Housing Material / Cable Glands F2 Field-mount / Single compartment / Aluminium / NPT 1/2 in.
- Protection Class Transmitter / Protection Class Sensor 70 IP 67 / IP 67
- Power Supply C 100 ... 230 V AC, 60 Hz
- Display 2 Display with Keypad
- Outputs G0 Current out (active/passive), 2x Digitial out (passive), HART
- Potable Water and Food & Beverage Approvals CWY Without
- Other Options K0 Without
- Documentation Language M5 English
- Device Identification Plate T1 Stainless steel
- Temperature Range of Installation / Ambient Temp Range TK1 Standard design / -20 ... 60 °C (-4 ... 140 °F)
- Remote Transmitter Mounting Kit B0 Without
Downloads